Pets: visitors should be aware that a domestic cat lives at this property. The
cat will be kept away from visitors, but anyone with a cat allergy should be
aware and take appropriate precautions.
Home Overview
● Home Type: Semi-detached
● Year Built: 1962
● Size: 143 sq metres/ 4 bedrooms
Renovation History:
○ 1992: front and back single storey extensions
○ 2008: replacement double glazing throughout
○ 2008: improved loft insulation
○ 2011: 12 PV panels to roof
○ 2012: two-storey extension to the side
○ 2018: 7Kw EV charger fitted (EV purchased: Nissan Leaf)
○ 2019: 5Kwh solar battery installed
Green Features
Energy Efficiency
Insulation:
Cavity walls: as standard for build and extension dates
Loft: >250mm
Windows and Doors: uPVC, double glazed windows
Heating System: Gas boiler with radiators and Hive controls
Cooling System: N/A
Lighting: low energy bulbs/LEDs throughout, and natural light where possible (Velux windows in single storey extensions)
Thermal imaging survey: to identify areas of heat loss.
Renewable Energy
Solar Panels: 12 PV panels
Battery Storage: Sonnen 5Kwh
Air source heat pump: have now installed an air source heat pump to replace the gas boiler for heating and hot water. Heat loss surveys have been conducted and system designs produced – these can be viewed.
Solar diverter: installed a solar diverter (MyEddi) to maximise solar benefit including powering hot water immersion.
Other useful information:
● EV charging station on side of house to charge EV – Nissan LEAF 62Kw
Future Plans
Upcoming Projects:
Future Plans
Upcoming Projects:
Air tightness survey: to identify location of draughts and remove them.
Long-Term Goals: remove gas supply from the property completely to remove need to pay a standing charge.